• Filter Drier Danfoss DML 032

    Filter Drier Danfoss DML 165

    Kami menjual Filter Drier Danfoss DML 165

    DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .

    APPLICATIONS

    • Traditional refrigeration
    • Air Conditioning units
    • Transport Refrigeration
    • High Drying capacity avoiding the risk of acid formation in the refrigeration system
    • All danfoss filter driers have end caps designed for greater protection and easy removal
    • Wide range with size : 1.5-75 cubic inches
    • Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
    • 100% 3A molecular sieve core
    • Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
    • PS/MWP up to 46 bar/667 psig
    • Available with flare, solder ( pure cooper, cu-plated ) connections .
    Rp0,00
  • Filter Drier Danfoss DML 032

    Filter Drier Danfoss DML 304

    01

    Kami menjual Filter Drier Danfoss DML 304

    DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .

    APPLICATIONS

    • Traditional refrigeration
    • Air Conditioning units
    • Transport Refrigeration
    • High Drying capacity avoiding the risk of acid formation in the refrigeration system
    • All danfoss filter driers have end caps designed for greater protection and easy removal
    • Wide range with size : 1.5-75 cubic inches
    • Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
    • 100% 3A molecular sieve core
    • Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
    • PS/MWP up to 46 bar/667 psig
    • Available with flare, solder ( pure cooper, cu-plated ) connections .
    Rp0,00

    Filter Drier Danfoss DML 304

    01
    Rp0,00
  • Filter Drier Danfoss DML 032

    Filter Drier Danfoss DML 304

    Kami menjual Filter Drier Danfoss DML 304

    DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .

    APPLICATIONS

    • Traditional refrigeration
    • Air Conditioning units
    • Transport Refrigeration
    • High Drying capacity avoiding the risk of acid formation in the refrigeration system
    • All danfoss filter driers have end caps designed for greater protection and easy removal
    • Wide range with size : 1.5-75 cubic inches
    • Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
    • 100% 3A molecular sieve core
    • Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
    • PS/MWP up to 46 bar/667 psig
    • Available with flare, solder ( pure cooper, cu-plated ) connections .
    Rp0,00
  • Filter Drier Danfoss DML 032

    Filter Drier Danfoss DML 305

    01

    Kami menjual Filter Drier Danfoss DML 305

    DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .

    APPLICATIONS

    • Traditional refrigeration
    • Air Conditioning units
    • Transport Refrigeration
    • High Drying capacity avoiding the risk of acid formation in the refrigeration system
    • All danfoss filter driers have end caps designed for greater protection and easy removal
    • Wide range with size : 1.5-75 cubic inches
    • Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
    • 100% 3A molecular sieve core
    • Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
    • PS/MWP up to 46 bar/667 psig
    • Available with flare, solder ( pure cooper, cu-plated ) connections .
    Rp0,00

    Filter Drier Danfoss DML 305

    01
    Rp0,00
  • Filter Drier Danfoss DML 306

    01

    DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .

    APPLICATIONS

    • Traditional refrigeration
    • Air Conditioning units
    • Transport Refrigeration
    • High Drying capacity avoiding the risk of acid formation in the refrigeration system
    • All danfoss filter driers have end caps designed for greater protection and easy removal
    • Wide range with size : 1.5-75 cubic inches
    • Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
    • 100% 3A molecular sieve core
    • Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
    • PS/MWP up to 46 bar/667 psig
    • Available with flare, solder ( pure cooper, cu-plated ) connections .
    Rp0,00

    Filter Drier Danfoss DML 306

    01
    Rp0,00
  • Low Pressure Gauge Danfoss KP 1 Auto

    Product Description

    KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

    Product Features
    • Ambient temperature:–40 – +65°C (+80°C for max. 2 hours). DIN-approved units:–40 – +65°C (+80°C for max. 2 hours). Max. working pressure = 17 bar Max. test pressure = 20 bar Contact load, AC: AC1: 16 A, 400 V AC3: 16 A, 400 V AC15: 10 A, 400 V Max. starting current (L.R.): 112 A, 400 V Contact load, DC: DC13: 12 W, 220 V control current.
    Rp0,00
  • Low Pressure Gauge Danfoss KP 1 Manual

    01
    Product Description

    KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

    Product Features
    • Ambient temperature:–40 – +65°C (+80°C for max. 2 hours). DIN-approved units:–40 – +65°C (+80°C for max. 2 hours). Max. working pressure = 17 bar Max. test pressure = 20 bar Contact load, AC: AC1: 16 A, 400 V AC3: 16 A, 400 V AC15: 10 A, 400 V Max. starting current (L.R.): 112 A, 400 V Contact load, DC: DC13: 12 W, 220 V control current
    Rp0,00

    Low Pressure Gauge Danfoss KP 1 Manual

    01
    Rp0,00
  • Selenoid Danfoss EVR 10 5/8″

    Selenoid Danfoss EVR 10 5/8″

    Kami menjual Selenoid Danfoss EVR 10 5/8″

    Product Description

    KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

    Product Features
    • Ambient temperature:–40 – +65°C (+80°C for max. 2 hours). DIN-approved units:–40 – +65°C (+80°C for max. 2 hours). Max. working pressure = 17 bar Max. test pressure = 20 bar Contact load, AC: AC1: 16 A, 400 V AC3: 16 A, 400 V AC15: 10 A, 400 V Max. starting current (L.R.): 112 A, 400 V Contact load, DC: DC13: 12 W, 220 V control current
    Rp0,00
  • Selenoid Danfoss EVR 10 5/8″

    Selenoid Danfoss EVR 15 7/8″

    Kami menjual Selenoid Danfoss EVR 15 7/8″

    Product Description

    KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

    Product Features
    • Ambient temperature:–40 – +65°C (+80°C for max. 2 hours). DIN-approved units:–40 – +65°C (+80°C for max. 2 hours). Max. working pressure = 17 bar Max. test pressure = 20 bar Contact load, AC: AC1: 16 A, 400 V AC3: 16 A, 400 V AC15: 10 A, 400 V Max. starting current (L.R.): 112 A, 400 V Contact load, DC: DC13: 12 W, 220 V control current
    Rp0,00
  • Selenoid Danfoss EVR 10 5/8″

    Selenoid Danfoss EVR 2 1/4″

    Kami menjual Selenoid Danfoss EVR 2 1/4″

    Product Description

    EVR (NC) is a normally closed, direct or servo operated solenoid valve for liquid, suction and hot gas lines with fluorinated refrigerants. EVR valves are supplied complete or as separate components, i.e. valve body, coil and flanges.

    Product Features
    • Refrigerants: R22/R407C, R404A/R507, R410A, R134a, R407A, R23. For other refrigerants, please contact Danfoss. Temperature of medium: -40 – +105°C (10 W / 12 W coil) Max. 130°C during defrosting. Min. opening differential pressure, EVR 2-3: 0.0 bar, EVR 6-22: 0.05 bar, EVR 25-32: 0.20 bar.
    Rp0,00
  • Selenoid Danfoss EVR 10 5/8″

    Selenoid Danfoss EVR 3 3/8″

    Kami menjual Selenoid Danfoss EVR 3 3/8″

    Product Description

    EVR (NC) is a normally closed, direct or servo operated solenoid valve for liquid, suction and hot gas lines with fluorinated refrigerants. EVR valves are supplied complete or as separate components, i.e. valve body, coil and flanges.

    Product Features
    • Refrigerants: R22/R407C, R404A/R507, R410A, R134a, R407A, R23. For other refrigerants, please contact Danfoss. Temperature of medium: -40 – +105°C (10 W / 12 W coil) Max. 130°C during defrosting. Min. opening differential pressure, EVR 2-3: 0.0 bar, EVR 6-22: 0.05 bar, EVR 25-32: 0.20 bar.
    Rp0,00
  • Selenoid Danfoss EVR 6 1/2″

    01
    Product Description

    EVR (NC) is a normally closed, direct or servo operated solenoid valve for liquid, suction and hot gas lines with fluorinated refrigerants. EVR valves are supplied complete or as separate components, i.e. valve body, coil and flanges.

    Product Features
    • Refrigerants: R22/R407C, R404A/R507, R410A, R134a, R407A, R23. For other refrigerants, please contact Danfoss. Temperature of medium: -40 – +105°C (10 W / 12 W coil) Max. 130°C during defrosting. Min. opening differential pressure, EVR 2-3: 0.0 bar, EVR 6-22: 0.05 bar, EVR 25-32: 0.20 bar.
    Rp0,00

    Selenoid Danfoss EVR 6 1/2″

    01
    Rp0,00
Open chat
Butuh Bantuan?
Selamat datang, perlu bantuan?