• Filter Drier Castel D330/5-305 5/8″

    FILTER DRIER DESCRIPTION

    Filter and liquid/humidity indicators are designed for isntalation on commersial refrigeration systems and civil and industrial air conditioning refrigeration systems employing group II refrigerants . Filter driers are available in a hermetically sealed version or with a solid exchangeable cartridge . Hermetically sealed filters are supplied in the standard drier version, series 43, anti-acid series 42, BI-derectional flow series 45. Filter with a solid exchangeable cartridge are available in packages of 1 to 4 standard drier, anti-acid or mechanical cartridges .

    Rp0,00
  • Expansion Valve Castel 2230/4E

    01
    The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:
    • Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
    • air conditioning systems
    • heat pump systems
    • liquid chillers

    Which use the following refrigerant fluds : R22,  R134A, R404A, R407C, R507 proper to the group II

    Rp0,00

    Expansion Valve Castel 2230/4E

    01
    Rp0,00
  • Expansion Valve Castel 2220/4E

    APPLICATION
    Castel thermostatic expansion valves series 22 regulate the flow of refrigerant liquid into evaporators; the liquid injection is controlled by the refrigerant superheat. The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:
    • Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
    • air conditioning systems
    • heat pump systems
    • liquid chillers

    Which use the following refrigerant fluds : R22,  R134A, R404A, R407C, R507 proper to the group II

    Rp0,00
  • Hot

    Expansion Valve Castel 2210/4E

    01
    APPLICATION
    Castel thermostatic expansion valves series 22 regulate the flow of refrigerant liquid into evaporators; the liquid injection is controlled by the refrigerant superheat. The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:
    • Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
    • air conditioning systems
    • heat pump systems
    • liquid chillers

    Which use the following refrigerant fluds : R22,  R134A, R404A, R407C, R507 proper to the group II

    OPERATION
    Castel thermostatic expansion valves act as throttle device between the high pressure and the low pressure sides of refrigeration systems and ensure that the rate of refrigerant fl ow into the evaporator exactly matches the rate of evaporation of liquid refrigerant in the evaporator.
    If the actual superheat is higher than the set point the valve feeds the evaporator with more liquid refrigerant, if the actual superheat is lower than the set point the valve decreases the fl ow of liquid refrigerant to the evaporator.
    Thus the evaporator is fully utilized and no liquid refrigerant may reach the compressor.
    Rp0,00

    Expansion Valve Castel 2210/4E

    01
    Rp0,00
  • Ball Valve Castel 7/8″

    DESCRIPTION

    The new Ball Valves 6570/6571 are designed for installation on commercial refrigerating systems and on civil and industrial conditioning plants, which use the following refrigerant fluids: R22, R134a, R404A, R407C, R410A, R507 proper to the group II.

    Ball valves are available in the following two types:

    • Type 6570 (full port) and type 6571 (reduced port) without access fitting.
    • Type 6570/A (full port) with access fitting, These ball valves are equipped with valve core 8394/A and blind nut 7020/20.
    Rp0,00
  • Ball Valve Castel 5/8″

    DESCRIPTION

    The new Ball Valves 6570/6571 are designed for installation on commercial refrigerating systems and on civil and industrial conditioning plants, which use the following refrigerant fluids: R22, R134a, R404A, R407C, R410A, R507 proper to the group II.

    Ball valves are available in the following two types:

    • Type 6570 (full port) and type 6571 (reduced port) without access fitting.
    • Type 6570/A (full port) with access fitting, These ball valves are equipped with valve core 8394/A and blind nut 7020/20.
    Rp0,00
  • Suction Line Accumulator Blue Green 7/8″

    Specification :

    BLR/AAS SUCTION LINE ACCUMULATORS Refrigeration 

    The BLUE U tube accumulator design is a result of extensive laboratory testing plus detailed investigation of the various accumulators currently available. It takes into account all of the requirements essential for heat pump applications, including safe holding volume (relative to the systems total charge), protected flow control for positive refrigerant and oil return, and minimum pressure drop across the accumulator. BLUE offers standard accumulator models designed for application on heat pump and refrigeration systems from 1 1/2 through 12 tons. Liquid refrigerant holding requirements of suction accumulator may vary by application. Because of the diversity in heat pump systems, accumulator capacity selection should be determined by actual testing. Consult BLUE for assistance if required.

    Rp0,00
  • Oil Separator BlueGreen 7/8″

    Kami menjual Oil Separator Blue Green BLR/AW-55877 ∅ 102 7/8″ ODS 1/4″ SAE

    Rp0,00
  • Selenoid Danfoss EVR 6 1/2″

    01
    Product Description

    EVR (NC) is a normally closed, direct or servo operated solenoid valve for liquid, suction and hot gas lines with fluorinated refrigerants. EVR valves are supplied complete or as separate components, i.e. valve body, coil and flanges.

    Product Features
    • Refrigerants: R22/R407C, R404A/R507, R410A, R134a, R407A, R23. For other refrigerants, please contact Danfoss. Temperature of medium: -40 – +105°C (10 W / 12 W coil) Max. 130°C during defrosting. Min. opening differential pressure, EVR 2-3: 0.0 bar, EVR 6-22: 0.05 bar, EVR 25-32: 0.20 bar.
    Rp0,00

    Selenoid Danfoss EVR 6 1/2″

    01
    Rp0,00
  • Low Pressure Gauge Danfoss KP 1 Manual

    01
    Product Description

    KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

    Product Features
    • Ambient temperature:–40 – +65°C (+80°C for max. 2 hours). DIN-approved units:–40 – +65°C (+80°C for max. 2 hours). Max. working pressure = 17 bar Max. test pressure = 20 bar Contact load, AC: AC1: 16 A, 400 V AC3: 16 A, 400 V AC15: 10 A, 400 V Max. starting current (L.R.): 112 A, 400 V Contact load, DC: DC13: 12 W, 220 V control current
    Rp0,00

    Low Pressure Gauge Danfoss KP 1 Manual

    01
    Rp0,00
  • Low Pressure Gauge Danfoss KP 1 Auto

    Product Description

    KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

    Product Features
    • Ambient temperature:–40 – +65°C (+80°C for max. 2 hours). DIN-approved units:–40 – +65°C (+80°C for max. 2 hours). Max. working pressure = 17 bar Max. test pressure = 20 bar Contact load, AC: AC1: 16 A, 400 V AC3: 16 A, 400 V AC15: 10 A, 400 V Max. starting current (L.R.): 112 A, 400 V Contact load, DC: DC13: 12 W, 220 V control current.
    Rp0,00
  • Filter Drier Danfoss DML 306

    01

    DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .

    APPLICATIONS

    • Traditional refrigeration
    • Air Conditioning units
    • Transport Refrigeration
    • High Drying capacity avoiding the risk of acid formation in the refrigeration system
    • All danfoss filter driers have end caps designed for greater protection and easy removal
    • Wide range with size : 1.5-75 cubic inches
    • Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
    • 100% 3A molecular sieve core
    • Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
    • PS/MWP up to 46 bar/667 psig
    • Available with flare, solder ( pure cooper, cu-plated ) connections .
    Rp0,00

    Filter Drier Danfoss DML 306

    01
    Rp0,00
Open chat
Butuh Bantuan?
Selamat datang, perlu bantuan?