• Filter Drier Castel D330/5-305 5/8″

    FILTER DRIER DESCRIPTION

    Filter and liquid/humidity indicators are designed for isntalation on commersial refrigeration systems and civil and industrial air conditioning refrigeration systems employing group II refrigerants . Filter driers are available in a hermetically sealed version or with a solid exchangeable cartridge . Hermetically sealed filters are supplied in the standard drier version, series 43, anti-acid series 42, BI-derectional flow series 45. Filter with a solid exchangeable cartridge are available in packages of 1 to 4 standard drier, anti-acid or mechanical cartridges .

    Rp0,00
  • Expansion Valve Castel 2230/4E

    01
    The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:
    • Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
    • air conditioning systems
    • heat pump systems
    • liquid chillers

    Which use the following refrigerant fluds : R22,  R134A, R404A, R407C, R507 proper to the group II

    Rp0,00

    Expansion Valve Castel 2230/4E

    01
    Rp0,00
  • Expansion Valve Castel 2220/4E

    APPLICATION
    Castel thermostatic expansion valves series 22 regulate the flow of refrigerant liquid into evaporators; the liquid injection is controlled by the refrigerant superheat. The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:
    • Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
    • air conditioning systems
    • heat pump systems
    • liquid chillers

    Which use the following refrigerant fluds : R22,  R134A, R404A, R407C, R507 proper to the group II

    Rp0,00
  • Hot

    Expansion Valve Castel 2210/4E

    01
    APPLICATION
    Castel thermostatic expansion valves series 22 regulate the flow of refrigerant liquid into evaporators; the liquid injection is controlled by the refrigerant superheat. The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:
    • Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
    • air conditioning systems
    • heat pump systems
    • liquid chillers

    Which use the following refrigerant fluds : R22,  R134A, R404A, R407C, R507 proper to the group II

    OPERATION
    Castel thermostatic expansion valves act as throttle device between the high pressure and the low pressure sides of refrigeration systems and ensure that the rate of refrigerant fl ow into the evaporator exactly matches the rate of evaporation of liquid refrigerant in the evaporator.
    If the actual superheat is higher than the set point the valve feeds the evaporator with more liquid refrigerant, if the actual superheat is lower than the set point the valve decreases the fl ow of liquid refrigerant to the evaporator.
    Thus the evaporator is fully utilized and no liquid refrigerant may reach the compressor.
    Rp0,00

    Expansion Valve Castel 2210/4E

    01
    Rp0,00
  • Ball Valve Castel 7/8″

    DESCRIPTION

    The new Ball Valves 6570/6571 are designed for installation on commercial refrigerating systems and on civil and industrial conditioning plants, which use the following refrigerant fluids: R22, R134a, R404A, R407C, R410A, R507 proper to the group II.

    Ball valves are available in the following two types:

    • Type 6570 (full port) and type 6571 (reduced port) without access fitting.
    • Type 6570/A (full port) with access fitting, These ball valves are equipped with valve core 8394/A and blind nut 7020/20.
    Rp0,00
  • Ball Valve Castel 5/8″

    DESCRIPTION

    The new Ball Valves 6570/6571 are designed for installation on commercial refrigerating systems and on civil and industrial conditioning plants, which use the following refrigerant fluids: R22, R134a, R404A, R407C, R410A, R507 proper to the group II.

    Ball valves are available in the following two types:

    • Type 6570 (full port) and type 6571 (reduced port) without access fitting.
    • Type 6570/A (full port) with access fitting, These ball valves are equipped with valve core 8394/A and blind nut 7020/20.
    Rp0,00
  • Suction Accumulator Emerson A-AS 1086-9 5/8″

    The A-AS protects the compressor  from liquid slugging and is used with CFC, HCFC and HFC refrigerants . It is available for systems through 28 tons nominal capacity .

    FEATURES

    • Designed to operate in a range of + 40oF to -40oF evaporator temperature
    • Fusible Flug on larger diameter units
    • Solid copper conections
    • Corrosion Resistant epoxy Powder paint finnish
    • Inlet deflector direct refrigerant flow to prevent internal spalshing and aid in the collection of refrigerant oil

    SPECIFICATIONS

    • Maximum working pressure : 450 psig
    • Fusible plug temperature : 430oF
    • UL/CUL file number : SA 10225
    Rp0,00
  • Oil Separator Emerson AW.5590-11 STD 1 3/8″

    01

    OIL SEPARATOR

    A-W&A-F OIL SEPARATOR

    APPLICATION :

    • Multiple compressor rack for supermarkets and air conditioning
    • System with long refrigerant lines
    • Systems with inherent oil return problems
    • Ultra-Low temperature systems
    • For use with HCFCs, HFCs and their lubricants

    FEATURES

    • Hermetic Welded or accessible bolted frange construction
    • Solid copper connections
    • Corrosion Resistant Paint

    SPECIFICATIONS

    • Maximum Working Pressure : 450 psig
    • U.L listed
    • C.S.A Listed ( #LR100624 )
    Rp0,00
  • Filter Drier Emerson EK 306-STD 5/8″

    The EK liquid line filter drier is a premium compacted bead filter drier with a 20 micron outlet pad for maximum filtration . The EK is a premium universal replacement luquid line filter drier for CFC, HCFC, and HFC refrigerant including R-12, R-134A, R-22, R-404A, R-407C, R-410A, R-500, R-502 and R-507 .

    FEATURES

    • Filtration first for more effective use of surface area of desiccant .
    • High moisture and acid removal capacity .
    • Solid copper connections .
    • Corrosion resistant epoxy powder paint finish
    • Approved for POE oils with copeland compressor .
    • Shock resistant steel shell contruction .

    SPECIFICATION

    • Desiccant Blend – Optimized for high water capacity and acid capacity .
    • filtration : 20 microns
    • Maximum working pressure : 680 psgi
    • UL/CUL file number : SA 3124
    Rp0,00
  • Expansion Emerson TJRE 18 HW

    01

    The T-Series take-apart valves, with adjustable superheat and replaceable, interchangeable components are ideal for original equipment and field replacements in air conditioning, heart pump and refrigeration applications .

    FEATURES

    • Take-Apart contruction for easy field service
    • External superheat adjustment
    • Bi-Flow capability
    • Stainless Steel power assembly up to 18 tons

    OPTIONS

    • Interchangeable, Replaceable cages
    • Interchangeable Body flanges
    • Interchangeable power assemblies
    • 1/4 to 100 ton capacity

    SPECIFICATIONS

    • Maximum Working pressure : 450 psig
    • Torque : 300 in.ib
    Rp0,00

    Expansion Emerson TJRE 18 HW

    01
    Rp0,00
  • Oli Suniso 5 GS ( 4 ltr )

    Oli Suniso 3 GS ( 4 ltr )

    Oli Suniso 3GS

    Suniso oil seri GS merupakan minyak pelumas (mineral oil) untuk oli kompresor AC dengan kualitas premium, dirancang untuk digunakan sebagai oli kompresor pendingin.

    • Oli SUNISO seri GS mampu bekerja dengan baik pada sistem yang menggunakan pendingin HCFC dan CFC, seperti R22, R502 dan R12 ,menunjukkan stabilitas yang sangat baik dan bekerja tanpa masalah di sistem pendingin menggunakan yang menggunkan refrigerant di atas. Selain itu, SUNISO GS juga berfungsi sangat baik pada pendingin alami seperti R717 amonia, R600a isobutane dan R290 propane.
    • Oli SUNISO seri GS diproses dari minyak mentah nafta ,diproses dengan menggunakan metode khusus , sehingga menjamin pelumasan yang sangat baik.
    • Oli SUNISO seri GS juga telah diterima disetujui oleh semua produsen AC, kulkas, freezer, ternama di dunia.

    suniso

    1 Chemical Stability
    Untuk menolak reaksi kimia dengan pendingin atau bahan lain biasanya hadir dalam sistem.
    2 Thermal Stability
    Untuk menghilangkan deposit karbon yang berlebihan pada hot spot kompresor seperti katup atau port debit.
    3 Low Wax Content
    Untuk mencegah pemisahan lilin flokulan dari campuran minyak-refrigeran pada titik-titik suhu rendah dalam sistem.
    4 Low Pour Point
    Untuk mencegah minyak terpisah dari mengental di garis refrigerant.
    5 High Dielectric Strength
    Untuk memastikan sifat isolasi yang baik. Dalam unit kedap udara, campuran minyak-refrigeran berfungsi sebagai isolator antara motor dan tubuh kompresor.
    6 Proper Viscosity
    Bahkan ketika diencerkan dengan pendingin sehingga untuk memastikan kekuatan film tinggi pada suhu operasi yang tinggi dan sekaligus memberikan fluiditas yang baik di bawah kondisi operasi yang paling dingin.
    7 No Contamination
    Untuk mencegah jaringan parut dari permukaan bantalan, ditusuk dari garis atau port minyak dan kerusakan umum.
    Rp0,00
  • Oli Suniso 5 GS ( 4 ltr )

    Oli Suniso 4 GS ( 4 ltr )

    01

    Oli Suniso 4GS

    Suniso oil seri GS merupakan minyak pelumas (mineral oil) untuk oli kompresor AC dengan kualitas premium, dirancang untuk digunakan sebagai oli kompresor pendingin.

    • Oli SUNISO seri GS mampu bekerja dengan baik pada sistem yang menggunakan pendingin HCFC dan CFC, seperti R22, R502 dan R12 ,menunjukkan stabilitas yang sangat baik dan bekerja tanpa masalah di sistem pendingin menggunakan yang menggunkan refrigerant di atas. Selain itu, SUNISO GS juga berfungsi sangat baik pada pendingin alami seperti R717 amonia, R600a isobutane dan R290 propane.
    • Oli SUNISO seri GS diproses dari minyak mentah nafta ,diproses dengan menggunakan metode khusus , sehingga menjamin pelumasan yang sangat baik.
    • Oli SUNISO seri GS juga telah diterima disetujui oleh semua produsen AC, kulkas, freezer, ternama di dunia.

    suniso

    1 Chemical Stability
    Untuk menolak reaksi kimia dengan pendingin atau bahan lain biasanya hadir dalam sistem.
    2 Thermal Stability
    Untuk menghilangkan deposit karbon yang berlebihan pada hot spot kompresor seperti katup atau port debit.
    3 Low Wax Content
    Untuk mencegah pemisahan lilin flokulan dari campuran minyak-refrigeran pada titik-titik suhu rendah dalam sistem.
    4 Low Pour Point
    Untuk mencegah minyak terpisah dari mengental di garis refrigerant.
    5 High Dielectric Strength
    Untuk memastikan sifat isolasi yang baik. Dalam unit kedap udara, campuran minyak-refrigeran berfungsi sebagai isolator antara motor dan tubuh kompresor.
    6 Proper Viscosity
    Bahkan ketika diencerkan dengan pendingin sehingga untuk memastikan kekuatan film tinggi pada suhu operasi yang tinggi dan sekaligus memberikan fluiditas yang baik di bawah kondisi operasi yang paling dingin.
    7 No Contamination
    Untuk mencegah jaringan parut dari permukaan bantalan, ditusuk dari garis atau port minyak dan kerusakan umum.
    Rp0,00

    Oli Suniso 4 GS ( 4 ltr )

    01
    Rp0,00
Open chat
Butuh Bantuan?
Selamat datang, perlu bantuan?