• Compressor Maneurop Danfoss MT 144-4VM

    Compressor Maneurop Danfoss MT 32-4VM

    Specification :

    Type Code MT
    Net weight 25.00 Kg
    Approval standards CCC; CE; UL
    Brand technique Reciprocating compressor
    Capacity control Fixed speed
    Colour Blue
    Configuration code Single
    Connection type Rotolock
    Cylinder 1
    Diameter [mm] 224
    Discharge connection height [mm] 68
    Discharge connection mounting torque [Nm] 80
    Discharge connection pipe size [in] 1/2
    Discharge connection rotolock size [in] 1
    Discharge connection size [in] 1
    Discharge connection sleeve pipe size [in] 1/2
    Drawing number 8501024e
    Economizer No
    Factory HP [bar] 25
    Factory LP [bar] 25
    Fitting remark (shipped with rotolock version only)
    Fitting sleeve ODF
    Fitting standard Rotolock
    Frequency [Hz] 50/60
    GP LP torque [Nm] 15
    Gauge port HP None
    Gauge port LP Schrader
    Generation code D
    Glass mounting Threaded
    Glass torque [Nm] 50
    Gross weight 26.25 Kg
    High value of nominal voltage at 50Hz [V] 400
    High value of nominal voltage at 60Hz [V] 460
    High value of voltage range at 50Hz [V] 460
    High value of voltage range at 60Hz [V] 506
    IP protection class IP55 (with cable gland)
    LRA 25 A
    Low value of nominal voltage at 50Hz [V] 380
    Low value of nominal voltage at 60Hz [V] 460
    Low value of voltage range at 50Hz [V] 340
    Low value of voltage range at 60Hz [V] 414
    MCC 8 A
    Model number MT32JF4DVE
    Motor protection Internal overload protector
    Mounting torque [Nm] 15
    Nominal cooling capacity 60 kBTU/h 33.11
    Nominal cooling capacity at 50Hz 7.3
    Nominal cooling capacity at 60Hz 9.7
    Number of starts per hour [Max] 12
    Oil charge [L] 0.95
    Oil equalization 3/8” flare SAE
    Oil equalization torque [Nm] 30
    Oil reference 160P
    Packaging height [mm] 500
    Packaging length [mm] 1150
    Packaging weight [Kg] 331
    Packaging width [mm] 800
    Packing format Industrial pack
    Packing quantity 12
    Phase 3
    Power connections Spade
    Refrigerant R22
    Refrigerant charge [kg] [Max] 2.5
    Relief valve None
    Rotational speed at 50Hz [rpm] 2900
    Rotational speed at 60Hz [rpm] 3500
    Rp0,00
  • Check Valve Danfoss NRV 6 1/4″

    DESCRIPTION

    NRV and NRVH can be used in liquid, suction and hot gas lines in refrigeration and air conditioning plants with fluorinated refrigerants. NRV and NRVH can be supplied with flare and solder connections. They are also available with oversize solder connections providing flexibility in the use of check valves.

    Rp0,00
  • Low Pressure Gauge Danfoss KP 1 Auto

    Product Description

    KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

    Product Features
    • Ambient temperature:–40 – +65°C (+80°C for max. 2 hours). DIN-approved units:–40 – +65°C (+80°C for max. 2 hours). Max. working pressure = 17 bar Max. test pressure = 20 bar Contact load, AC: AC1: 16 A, 400 V AC3: 16 A, 400 V AC15: 10 A, 400 V Max. starting current (L.R.): 112 A, 400 V Contact load, DC: DC13: 12 W, 220 V control current.
    Rp0,00