-
4 × Rp0,00
-
3 × Rp0,00
-
3 × Rp0,00
-
5 × Rp0,00
-
9 × Rp0,00
-
1 × Rp0,00
-
2 × Rp0,00
-
1 × Rp0,00
-
1 × Rp0,00
-
5 × Rp0,00
-
2 × Rp0,00
-
1 × Rp0,00
-
3 × Rp0,00
-
4 × Rp0,00
-
4 × Rp0,00
-
3 × Rp0,00
-
5 × Rp0,00
-
1 × Rp0,00
-
1 × Rp0,00
-
1 × Rp0,00
-
4 × Rp0,00
-
2 × Rp0,00
-
2 × Rp0,00
-
2 × Rp0,00
-
1 × Rp0,00
-
1 × Rp0,00
-
2 × Rp0,00
-
3 × Rp0,00
-
1 × Rp0,00
-
3 × Rp0,00
-
1 × Rp0,00
-
2 × Rp0,00
-
1 × Rp0,00
-
1 × Rp0,00
-
1 × Rp0,00
Best Seller Items
-
Compressor Manuerop Danfoss MT 64-4VM
Kami menjual Compressor Manuerop Danfoss MT 64-4VM
-
Pipa Set 1/4×5/8x30M HD Inverter
Kami menjual Pipa Set 2-2.5HP 1/4×5/8x30M HD Inverter
Rp0,00 -
Pipa Tembaga Roll 3/16″ HD
Kami menjual 3/16” hd (4.76mm) x0.76mmx15m
Rp0,00Pipa Tembaga Roll 3/16″ HD
Rp0,00 -
Oil Emkarate RL 100 H ( 5 LTR )
Kami menjual Oil Emkarate RL 100 H ( 5 LTR )
The Emkarate family of lubricants is a wide range of polyol ester refrigeration oil products. They are designed specifically for use with HFC refrigerants, developed to meet the performance demands of the refrigeration industry. This superior performance is achieved with basefluids that are specifically formulated to deliver optimum performance with minimal additive levels.
The requirements of today’s refrigeration and air conditioning compressor lubricants are complex. They must be compatible and miscible with the HFC refrigerants, and they must be compatible and miscible with CFC’s and HCFC’s as well as mineral and alkylbenzene oils. Polyol ester lubricants meet these needs, and the EMKARATE RL line is the preferred choice. Working in close collaboration with compressor and system manufacturers, these OEM-approved POE lubricants cover a wide viscosity range from 7 cSt (35-40 SUS) to 220 cSt (1100 SUS) to suit most applications. The lubricants have excellent thermal and chemical stability, and are compatible with a wide range of elastomers, polymeric materials and other materials of construction. Additionally, then higher viscosity index is an indication that their effective viscosity will not change drastically with the wide swings in temperature seen by most typical refrigeration and air conditioning systems. They are the preferred choice for servicing and retrofitting existing equipment as well as for OEM charging.
Rp0,00 -
Filter Drier Danfoss DML 304
Kami menjual Filter Drier Danfoss DML 304
DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .
APPLICATIONS
- Traditional refrigeration
- Air Conditioning units
- Transport Refrigeration
- High Drying capacity avoiding the risk of acid formation in the refrigeration system
- All danfoss filter driers have end caps designed for greater protection and easy removal
- Wide range with size : 1.5-75 cubic inches
- Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
- 100% 3A molecular sieve core
- Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
- PS/MWP up to 46 bar/667 psig
- Available with flare, solder ( pure cooper, cu-plated ) connections .
Rp0,00Filter Drier Danfoss DML 304
Rp0,00 -
Filter Drier Danfoss DML 305
Kami menjual Filter Drier Danfoss DML 305
DML ELMINATOR hermetic filter driers protect refrigeration and air conditioning systems from moisture, acids and solid particles, eleminating harmful chemical reaction and abrasive impurities . DML hermetic filter driers, with a 100% solid molecular sieve core, are recommended for use with HFO, HC, HFC and HCFC refrigerants . They are hermetic and available in many sizes and connection types .
APPLICATIONS
- Traditional refrigeration
- Air Conditioning units
- Transport Refrigeration
- High Drying capacity avoiding the risk of acid formation in the refrigeration system
- All danfoss filter driers have end caps designed for greater protection and easy removal
- Wide range with size : 1.5-75 cubic inches
- Corrosion resistant powder-painted finish, tested for 500 hrs in salt spray
- 100% 3A molecular sieve core
- Recommended for use with HFO, HC, HFC, and HCFC refrigerants ( face seal connectors for HFO refrigerants available upon request,please contact your sales representative )
- PS/MWP up to 46 bar/667 psig
- Available with flare, solder ( pure cooper, cu-plated ) connections .
Rp0,00Filter Drier Danfoss DML 305
Rp0,00
-
Selenoid Valve Castel 5/8″
SELENOID VALVES DESCRIPTION
Solenoid valves are designed for instalation on commercial refrigeration systems and civil and industrial air conditioning systems employing the following refrigerants : R22, R134A, R404A, R407C, 410A, R507 in group II . contact castel’s technical office for information on specific applications with refrigerant which are not listed above but do belong to group II . Available in normally closed org NC and normally open or no versions, with connections from 1/4″ to 2 1/8″ and vast range of reels and connectors .
Rp0,00Selenoid Valve Castel 5/8″
Rp0,00 -
Oil Separator Castel 7/8″
DESCRIPTION
Castel offers a vast range of oil management and control products: oil separators, oil level regulators, oil filters and oil reserves.
All products are compatible with HFC refrigerants, and particularly R134a, R404A, R407C, R507 and R410A mixed with POE oils or CFC and HCFC refrigerants mixed with mineral oils.Rp0,00Oil Separator Castel 7/8″
Rp0,00 -
Filter Drier Castel D330/5-305 5/8″
FILTER DRIER DESCRIPTION
Filter and liquid/humidity indicators are designed for isntalation on commersial refrigeration systems and civil and industrial air conditioning refrigeration systems employing group II refrigerants . Filter driers are available in a hermetically sealed version or with a solid exchangeable cartridge . Hermetically sealed filters are supplied in the standard drier version, series 43, anti-acid series 42, BI-derectional flow series 45. Filter with a solid exchangeable cartridge are available in packages of 1 to 4 standard drier, anti-acid or mechanical cartridges .
Rp0,00 -
Expansion Valve Castel 2230/4E
The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:- Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
- air conditioning systems
- heat pump systems
- liquid chillers
Which use the following refrigerant fluds : R22, R134A, R404A, R407C, R507 proper to the group II
Rp0,00 -
Expansion Valve Castel 2220/4E
APPLICATIONCastel thermostatic expansion valves series 22 regulate the flow of refrigerant liquid into evaporators; the liquid injection is controlled by the refrigerant superheat. The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:- Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
- air conditioning systems
- heat pump systems
- liquid chillers
Which use the following refrigerant fluds : R22, R134A, R404A, R407C, R507 proper to the group II
Rp0,00 -
Expansion Valve Castel 2210/4E
APPLICATIONCastel thermostatic expansion valves series 22 regulate the flow of refrigerant liquid into evaporators; the liquid injection is controlled by the refrigerant superheat. The new Castel “22” series are designed to work with interchangeable orifice assembly, to provide flexibility in selection of capacities, and can be used in a wide range of applications as listed below:- Refrigeration systems display cases in supermarkets, freezer, ice cream and ice maker machines , transport refrigeration
- air conditioning systems
- heat pump systems
- liquid chillers
Which use the following refrigerant fluds : R22, R134A, R404A, R407C, R507 proper to the group II
OPERATIONCastel thermostatic expansion valves act as throttle device between the high pressure and the low pressure sides of refrigeration systems and ensure that the rate of refrigerant fl ow into the evaporator exactly matches the rate of evaporation of liquid refrigerant in the evaporator.If the actual superheat is higher than the set point the valve feeds the evaporator with more liquid refrigerant, if the actual superheat is lower than the set point the valve decreases the fl ow of liquid refrigerant to the evaporator.Thus the evaporator is fully utilized and no liquid refrigerant may reach the compressor.Rp0,00 -
Ball Valve Castel 7/8″
DESCRIPTION
The new Ball Valves 6570/6571 are designed for installation on commercial refrigerating systems and on civil and industrial conditioning plants, which use the following refrigerant fluids: R22, R134a, R404A, R407C, R410A, R507 proper to the group II.
Ball valves are available in the following two types:
- Type 6570 (full port) and type 6571 (reduced port) without access fitting.
- Type 6570/A (full port) with access fitting, These ball valves are equipped with valve core 8394/A and blind nut 7020/20.
Rp0,00Ball Valve Castel 7/8″
Rp0,00 -
Ball Valve Castel 5/8″
DESCRIPTION
The new Ball Valves 6570/6571 are designed for installation on commercial refrigerating systems and on civil and industrial conditioning plants, which use the following refrigerant fluids: R22, R134a, R404A, R407C, R410A, R507 proper to the group II.
Ball valves are available in the following two types:
- Type 6570 (full port) and type 6571 (reduced port) without access fitting.
- Type 6570/A (full port) with access fitting, These ball valves are equipped with valve core 8394/A and blind nut 7020/20.
Rp0,00Ball Valve Castel 5/8″
Rp0,00 -
Suction Line Accumulator Blue Green 7/8″
Specification :
BLR/AAS SUCTION LINE ACCUMULATORS Refrigeration
The BLUE U tube accumulator design is a result of extensive laboratory testing plus detailed investigation of the various accumulators currently available. It takes into account all of the requirements essential for heat pump applications, including safe holding volume (relative to the systems total charge), protected flow control for positive refrigerant and oil return, and minimum pressure drop across the accumulator. BLUE offers standard accumulator models designed for application on heat pump and refrigeration systems from 1 1/2 through 12 tons. Liquid refrigerant holding requirements of suction accumulator may vary by application. Because of the diversity in heat pump systems, accumulator capacity selection should be determined by actual testing. Consult BLUE for assistance if required.
Rp0,00 -
Oil Separator BlueGreen 7/8″
Kami menjual Oil Separator Blue Green BLR/AW-55877 ∅ 102 7/8″ ODS 1/4″ SAE
Rp0,00Oil Separator BlueGreen 7/8″
Rp0,00 -
Vacuum Pump Handen VP 190 3/4HP
Vacuum Pump Handen VP 190 3/4HP
Frequency: 50Hz / 60Hz
Flow Rate: 3CFM 85 1/min / 3.6CFM 100 1/min
Ultimate Vacuum: 150micron
Motor Power: 1/3HP
Oil Capacity: 330ml
Net Weight: 5.5Kg
Dimensions: 285x122x245 mm
Rp0,00 -
Steam Handen 20A
Kami menjual Steam Handen 20A
Specification :
Motor Kapasitas: 200 Watt | Tekanan: 50 Psi / 700 Kg / Cm | Discharge: 2.9/3.5 L / Min | Rpm: 1430 Rpm | Berat: 9 Kg
Rp0,00Steam Handen 20A
Rp0,00